bs6724 cable - 600/1000V mica tape XLPE insulation LSHF cables
British standard cable; for adopting thermosetting insulation and affected by fire exudes a small amount of smoke and corrosive gases 600/ 1000V and 1900/3300V armoured cable specification.
 
Cross linked polyethylene (XLPE) insulation, polyvinyl chloride (PVC) sheath or low smoke halogen free sheath (LSHF) cables
 
Application:
 
The cable is suitable for certain areas where circuit integrity is critical in maintaining power supply. The cable is mainly used for emergency lighting, control and power circuit, power station, fire alarm system, underground tunnel, fire elevator, escalator, and high-rise building wiring cable.
 
Fire protection standard:
 
Line integrity IEC 60331-21; BS 6387 CWZ; DIN VDE 0472- 
814(FE180); BS 8434-2 (120mins); BS 5839-1 Clause 26 2e; 
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1
The route of applying mechanical shock integrity EN 50200(PH120); CEI 20-36/4-0
Mechanical shock and water injection line integrity EN 50200
System integrity Depends on the laying systems DIN 4102-12, E30
  Flame retardant (single vertical cable testing) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; 
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); 
NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
  Reduce the spread of fire (vertical installation into cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; 
BS EN 60332-3-24; VDE 0482-332-3; 
NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; 
DIN VDE 0482-266-2-4
  Halogen free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
  No corrosive gases IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
  Minimum smoke release IEC 61034-1&2; EN 61034 -1&2; 
DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No poisonous gas NES 02-713; NF C 20-454

600/1000V mica tape XLPE insulation, low smoke halogen free sheathed power cable (single core)Rated voltage:
600/1000V
 
Cable structure:
Conductor: plain annealed copper wire, stranded wire accord with IEC (EN) 60228 class 2
Fire protection layer: mica tape covered in crosslinked polyethylene composite.
Inner sheath: in line with the 7655: BS thermoplastic low smoke halogen free composite LTS3 type.
Armour: aluminum wire armoured
Outer sheath: in line with the BS 7652 standard the thermoplastic plastic, low smoke halogen free composite LTS3 class
 
Physical and thermal properties:
Operating temperature range (fixed state): -30°C - 90°C
Installation temperature range (movement state): -20°C - 50°C
Minimum bending radius: 8 * OD
 
The structural parameters:
 
Conductor FFX300 1Z1Z1-R
Nominal cross-sectional area The number of stranded wire and diameter Conductor diameter Insulation thickness Unarmoured
Nominal diameter The nominal weight
mm2 No./mm mm mm mm kg/km
1.5 7/0.53 1.59 0.7 6.5 54
2.5 7/0.67 2.01 0.7 6.8 67
4 7/0.85 2.55 0.7 7.5 86
6 7/1.04 3.12 0.7 8.1 110
10 7/1.35 4.05 0.7 9.2 155
16 7/1.70 5.1 0.7 10.2 220
25 7/2.14 6.42 0.9 11.9 325
35 19/1.53 7.65 0.9 13.2 425
50 19/1.78 8.9 1 14.6 600
70 19/2.14 10.7 1.1 16.6 820
95 19/2.52 12.6 1.1 18.7 1100
120 37/2.03 14.21 1.2 20.5 1350
150 37/2.25 15.75 1.4 22.7 1640
185 37.2.52 17.64 1.6 25.5 2040
240 61/2.25 20.25 1.7 28.5 2650
300 61/2.52 22.68 1.8 31.5 3260
400 65/2.85 25.65 2 35.4 4130
500 61/3.20 28.8 2.2 39 5200
630 127/2.52 32.76 2.4 43.5 6600
800 127/2.85 37.05 2.6 48.5 8300
1000 127/3.20 41.6 2.8 53.5 10000